P O W E R  V A C U U M  E J E C T O R    9 4 8   m b a r   –   S E R I E S  V P 1 0



The compact lightweight...

- With silencer

With 5.5 bar the VP10 is able to produce 95 % (948 mbar) of vacuum power. With its compact design and simple construction it fits into the smallest of spaces to achieve great vacuum performance – try it for yourself.
The VP1X has an integrated counter blow function to ensure that the suction cup releases the part quickly for very fast cycle times.
More models with different vacuum performances/volumes are available here.
Matching fittings can be found under Accessories and hoses under Fluid Technology.



VP10
VP1X



Matching vacuum switch VSMP >>>


Operating pressure: 5.5 bar · Operating temperature: -10 °C...+80 °C

Order-No.

Version

Air consumption

[l norm./min.]
Max.
vacuum level*
[mbar]
Max.
vacuum flow
[l norm./min.]
Noise level
[dB]
VP10-060H standard 22.7 948 14.2 64
VP10-090H standard 51.0 948 34.0 64
VP10-100H standard 79.3 948 56.6 64
VP10-150H standard 135.9 948 90.6 64
VP1X-060H with blow-off function 22.7 948 14.2 64
VP1X-090H with blow-off function 51.0 948 34.0 64
VP1X-100H with blow-off function 79.3 948 56.6 64
VP1X-150H with blow-off function 135.9 948 90.6 64
*Please bear in mind that the vacuum decreases by 12 mbar per each 100 m above sea level.


Vacuum flow [l norm./min.] vs. vacuum level [mbar]

Order-No.

0
mbar
102
mbar
203
mbar
305
mbar
406
mbar
508
mbar
609
mbar
711
mbar
813
mbar
914
mbar
948
mbar
VP10-060H/
VP1X-060H
14.2 10.8 9.1 8.5 7.6 6.5 5.7 3.7 1.4 0.6 0
VP10-090H/
VP1X-090H
34.0 28.3 26.9 25.5 24.1 21.2 19.8 14.7 13.3 5.7 0
VP10-100H/
VP1X-100H
56.6 52.4 49.6 44.5 39.6 35.4 29.7 23.8 19.8 9.9 0
VP10-150H/
VP1X-150H
90.6 79.3 70.8 65.1 56.6 45.3 39.6 34.0 22.7 14.6 0


Evacuation time in seconds based on 1 liter volume/mbar


Order-No.

0
mbar
102
mbar
203
mbar
305
mbar
406
mbar
508
mbar
609
mbar
711
mbar
813
mbar
914
mbar
948
mbar
VP10-060H/
VP1X-060H
0 0.5 1.1 1.8 2.6 3.6 4.8 6.5 8.7 14.5 27.9
VP10-090H/
VP1X-090H
0 0.2 0.4 0.7 1.1 1.7 2.3 3.3 4.6 7.8 9.9
VP10-100H/
VP1X-100H
0 0.1 0.2 0.4 0.6 0.9 1.4 1.9 2.8 5.9 8.9
VP10-150H/
VP1X-150H
0 0.1 0.1 0.2 0.3 0.5 0.8 1.6 1.9 2.9 4.4



*Please bear in mind that the vacuum decreases by 12 mbar per each 100 m above sea level.




Sample applications:
VP10 multi-handling pins
Sensitive handling of a halogen bulb