P O W E R  V A C U U M  E J E C T O R  W I T H  
F L O W  T H R O U G H  F U N C T I O N ,  A D J U S T A B L E

The sensitive one...

Sensitive parts (glass panes, paper) sometimes have to be suctioned with great care. This is a welcome task for the adjustable VDF vacuum ejector. The adjustability optimizes energy, holding power, and air consumption.
Despite the sensitivity the VDF is quite a guzzler. It transports, doses, or suctions even fluids, which makes it ideal for dosing, suctioning, and filling units.
For your specific requirement (food industry, pharma, medical branch etc.) we gladly deliver the VDF in particular materials like e.g. stainless steel (AISI 303, 304, 316, 316L), PVC or POM as well.
Delivery time and price on application.

Suitable screw joints see Accessories > Fittings; hoses see Fluid Technology.

Note: With maximum performance the connection cross-section of the air supply should be equal to the flow rate øA.



VDF


Operating pressure: 5.5 bar · Operating temperature: -10 °C...+80 °C

Order-No.


Air consumption

[l norm./min.]
Vacuum level

[mbar]
Vacuum flow

[l norm./min.]
Noise level
without silencer
Noise level
with silencer
Matching
silencer

Open flow
Sealed vacuum
Open flow
Sealed vacuum
VDF100 0 - 37 0 - 850 0 - 56.6 88 dB 76 dB 70 dB 68 dB ST4
VDF150 0 - 68 0 - 850 0 - 90.6 88 dB 90 dB 74 dB 68 dB ST4
VDF200 0 - 133 0 - 850 0 - 169.9 86 dB 100 dB 76 dB 80 dB  ST4
VDF250 0 - 235 0 - 850 0 - 283.2 90 dB 100 dB 82 dB 80 dB  ST4A2
VDF375 0 - 481 0 - 850 0 - 849.6 102 dB 104 dB 88 dB 82 dB  ST8B
VDF500 0 - 793 0 - 850 0 - 1699.2 96 dB 100 dB 82 dB 78 dB  ST12C
VDF750 0 - 1246 0 - 850 0 - 3398.4 112 dB 108 dB 98 dB 88 dB ST16C 



Order-No.

Dimensions
A B C D
[Ø mm]
E
[Ø mm]
F
[mm]
H
[mm]
J
[mm]
K
[mm]
M
[Ø mm]
VDF100 G1/8" G1/4" G1/4" 3.2 18.8 22.1 38.1 57.7 94.7 31.5
VDF150 G1/8" G1/4" G1/4" 3.7 18.8 22.1 38.1 57.7 94.7 31.5
VDF200 G1/8" G1/4" G1/4" 4.8 18.8 22.1 38.1 57.7 94.7 31.5
VDF250 G1/8" G1/4" G1/4" 6.7 18.8 22.1 38.1 57.7 94.7 31.5
VDF375 G3/8" G1/2" G1/2" 9.5 25.1 38.1 60.2 87.6 153.4 44.2
VDF500 G3/8" G1/2" G3/4" 12.7 31.5 38.1 63.5 94.0 153.9 50.0
VDF750 G1/2" G3/4" G1" 19.1 37.8 38.1 63.5 94.0 176.5 56.4



Vacuum flow [l norm./min.] vs. vacuum level [mbar]*

Order-No.
0 mbar 102 mbar 203 mbar 305 mbar 406 mbar 508 mbar 609 mbar 711 mbar 813 mbar 847 mbar
VDF100 56.6 51 45.3 39.6 36.8 34 31.2 21.2 7.1 0.0
VDF150 90.6 79.3 70.8 62.3 51 45.3 36.8 25.5 11.3 0.0
VDF200 169.9 158.6 141.6 118.9 102 85 73.6 51 25.5 0.0
VDF250 283.2 260.5 235.1 212.4 186.9 164.3 147.3 107.6 36.8 0.0
VDF375 849.6 764.6 708 651.4 594.7 509.8 453.1 311.5 85 0.0
VDF500 1699.2 1472.6 1274.4 1161.1 1076.2 991.2 793 538.1 141.6 0.0
VDF750 3398.4 2803.7 2350.6 2095.7 1755.8 1444.3 1302.7 962.9 254.9 0.0
*) Please bear in mind that the vacuum decreases by 12 mbar per each 100 m above sea level.


Evacuation time in seconds based on 1 liter volume/mbar

Order-No.
0   mbar 102 mbar 203 mbar 305 mbar 406 mbar 508 mbar 609 mbar 711 mbar 813 mbar 847 mbar
VDF100 0.0 0.1 0.3 0.5 0.7 1 1.4 1.9 3 3.7
VDF150 0.0 0.1 0.2 0.4 0.5 0.8 1.1 1.6 2.7 3.4
VDF200 0.0 0.0 0.1 0.1 0.2 0.3 0.5 0.7 1.1 1.3
VDF250 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.6 0.8
VDF375 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.5
VDF500 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2
VDF750 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2






*) Please bear in mind that the vacuum decreases by 12 mbar per each 100 m above sea level.



Sample applications:

VDF with refrac bricks
VDF handing out breakfast