The sensitive one... Sensitive parts (glass panes, paper) sometimes have to be suctioned with great care. This is a welcome task for the adjustable VDF vacuum ejector. The adjustability optimizes energy, holding power, and air consumption. |
VDF |
Air consumption
[l norm./min.] |
[mbar] |
[l norm./min.] |
Noise level
without silencer |
Noise level
with silencer |
Matching
silencer |
|||
Open flow
|
Sealed vacuum
|
Open flow
|
Sealed vacuum
|
|||||
VDF100 | 0 - 37 | 0 - 850 | 0 - 56.6 | 88 dB | 76 dB | 70 dB | 68 dB | ST4 |
VDF150 | 0 - 68 | 0 - 850 | 0 - 90.6 | 88 dB | 90 dB | 74 dB | 68 dB | ST4 |
VDF200 | 0 - 133 | 0 - 850 | 0 - 169.9 | 86 dB | 100 dB | 76 dB | 80 dB | ST4 |
VDF250 | 0 - 235 | 0 - 850 | 0 - 283.2 | 90 dB | 100 dB | 82 dB | 80 dB | ST4A2 |
VDF375 | 0 - 481 | 0 - 850 | 0 - 849.6 | 102 dB | 104 dB | 88 dB | 82 dB | ST8B |
VDF500 | 0 - 793 | 0 - 850 | 0 - 1699.2 | 96 dB | 100 dB | 82 dB | 78 dB | ST12C |
VDF750 | 0 - 1246 | 0 - 850 | 0 - 3398.4 | 112 dB | 108 dB | 98 dB | 88 dB | ST16C |
Dimensions
|
||||||||||
A | B | C | D [Ø mm] |
E [Ø mm] |
F [mm] |
H [mm] |
J [mm] |
K [mm] |
M
[Ø mm] |
|
VDF100 | G1/8" | G1/4" | G1/4" | 3.2 | 18.8 | 22.1 | 38.1 | 57.7 | 94.7 | 31.5 |
VDF150 | G1/8" | G1/4" | G1/4" | 3.7 | 18.8 | 22.1 | 38.1 | 57.7 | 94.7 | 31.5 |
VDF200 | G1/8" | G1/4" | G1/4" | 4.8 | 18.8 | 22.1 | 38.1 | 57.7 | 94.7 | 31.5 |
VDF250 | G1/8" | G1/4" | G1/4" | 6.7 | 18.8 | 22.1 | 38.1 | 57.7 | 94.7 | 31.5 |
VDF375 | G3/8" | G1/2" | G1/2" | 9.5 | 25.1 | 38.1 | 60.2 | 87.6 | 153.4 | 44.2 |
VDF500 | G3/8" | G1/2" | G3/4" | 12.7 | 31.5 | 38.1 | 63.5 | 94.0 | 153.9 | 50.0 |
VDF750 | G1/2" | G3/4" | G1" | 19.1 | 37.8 | 38.1 | 63.5 | 94.0 | 176.5 | 56.4 |
Vacuum flow [l norm./min.] vs. vacuum level [mbar]*
Order-No. |
0 mbar | 102 mbar | 203 mbar | 305 mbar | 406 mbar | 508 mbar | 609 mbar | 711 mbar | 813 mbar | 847 mbar |
VDF100 | 56.6 | 51 | 45.3 | 39.6 | 36.8 | 34 | 31.2 | 21.2 | 7.1 | 0.0 |
VDF150 | 90.6 | 79.3 | 70.8 | 62.3 | 51 | 45.3 | 36.8 | 25.5 | 11.3 | 0.0 |
VDF200 | 169.9 | 158.6 | 141.6 | 118.9 | 102 | 85 | 73.6 | 51 | 25.5 | 0.0 |
VDF250 | 283.2 | 260.5 | 235.1 | 212.4 | 186.9 | 164.3 | 147.3 | 107.6 | 36.8 | 0.0 |
VDF375 | 849.6 | 764.6 | 708 | 651.4 | 594.7 | 509.8 | 453.1 | 311.5 | 85 | 0.0 |
VDF500 | 1699.2 | 1472.6 | 1274.4 | 1161.1 | 1076.2 | 991.2 | 793 | 538.1 | 141.6 | 0.0 |
VDF750 | 3398.4 | 2803.7 | 2350.6 | 2095.7 | 1755.8 | 1444.3 | 1302.7 | 962.9 | 254.9 | 0.0 |
Evacuation time in seconds based on 1 liter volume/mbar
Order-No. |
0 mbar | 102 mbar | 203 mbar | 305 mbar | 406 mbar | 508 mbar | 609 mbar | 711 mbar | 813 mbar | 847 mbar |
VDF100 | 0.0 | 0.1 | 0.3 | 0.5 | 0.7 | 1 | 1.4 | 1.9 | 3 | 3.7 |
VDF150 | 0.0 | 0.1 | 0.2 | 0.4 | 0.5 | 0.8 | 1.1 | 1.6 | 2.7 | 3.4 |
VDF200 | 0.0 | 0.0 | 0.1 | 0.1 | 0.2 | 0.3 | 0.5 | 0.7 | 1.1 | 1.3 |
VDF250 | 0.0 | 0.0 | 0.0 | 0.1 | 0.1 | 0.1 | 0.2 | 0.3 | 0.6 | 0.8 |
VDF375 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 | 0.1 | 0.2 | 0.3 | 0.5 |
VDF500 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 | 0.1 | 0.2 | 0.2 |
VDF750 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 | 0.2 |
*) Please bear in mind that the vacuum decreases by 12 mbar per each 100 m above sea level.
Sample applications:
VDF with refrac bricks | ||
VDF handing out breakfast |